This is a summary report of all data for Mamont 1 Pad site 07.

See Interpreting field and lab reports for more detailed information about the data in these tables.

Field Data Summary

Below is a field data summary report for this site, including averages and standard deviations of all measureable parameters. Collector initials are explained here.

Date Collector(s) Time pH TDS (ppm) Cond.(μS) Temp.(°C) Comments
2012/03 (Q04) RC, AH 12:15 8.17 42 85 7.3 moderate flow
2012/06 (Q05) BF, AH 11:30 7.82 55 101 16.3 stagnant, no flow
2012/09 (Q06) BF, AH 11:40 dry[1]
2012/12 (Q07) BF, SD 11:47 8.10 35 70 7.6 moderate flow
2013/03 (Q08) DT, AH 11:30 7.01 36 72 5.0 moderate flow
2013/06 (Q09) DT, JV 11:29 7.88 53 112 18.7 very low flow
2013/09 (Q10) ASo, DT, JV 17:30 7.95 63 126 16.0 moderate flow
2013/12 (Q11) SD, BF 11:08 7.70 64 127 8.1 high flow
2014/03 (Q12) TH, BO, ET, DT 12:23 6.88 55 120 4.0 none
2014/06 (Q13) TH, DT, JV, MP 17:04 7.97 72 144 20.4 moderate flow
2014/09 (Q14) BO, ET, IT, BF 11:27 dry
2014/12 (Q15) BO, TH 12:48 7.66 45 90 7.5 high flow, cloudy
2015/03 (Q16) BO, BF 13:20 7.66 44 88 5.4 medium high flow
2015/06 (Q17) BO, GM, SW 14:13 7.41 52 126 16.5 high flow
2015/09 (Q18) BO, NH, SJ 11:44 dry
2015/12 (Q19) BO, PM 13:35 6.94 52 104 10.2 low, dry below point
2016/03 (Q20) BO, KL, JC 12:21 7.89 60 118 7.0 very low flow
2016/06 (Q21) BO, GO, MH 12:01 too low to sample
2016/09 (Q22) BO, CW, MH, SJ 17:00 dry
2016/12 (Q23) BO, MH, GO 11:29 6.28 46 95 6.7 extremely high flow from both upstream branches
2017/03 (Q24) BO, ST, SS 11:50 7.75 60 125 10.6 moderately high flow
2017/06 (Q25) BO, AL 12:02 7.16 42 83 16.8 very high flow from both feeder channels
2017/09 (Q26) BO, DM, EP, EG, SS 16:24 dry
2017/12 (Q27) BO, SS, ZH 11:40 7.16 74 149 5.8 low flow
2018/03 (Q28) BO, DM, EP, SS 11:34 7.40 57 114 5.0 medium flow
Averages: 7.52 53 108 10.3
Standard Deviations: 0.50 11 23 5.3

Notes

  1. ^ A site denoted as "dry" indicates an active sampling site that has little or no water present for field measurements.