Site K08

From Beaver Run Project
Jump to: navigation, search

This is a summary report of all data for Kuhns Pad site 08.

See Interpreting field and lab reports for more detailed information about the data in these tables.

Field Data Summary

Below is a field data summary report for this site, including averages and standard deviations of all measureable parameters. Collector initials are explained here.

Date Collector(s) Time pH TDS (ppm) Cond.(μS) Temp.(°C) Comments
2012/03 (Q04) RC, AH 8:10 7.38 40 80 4.5 low flow
2012/06 (Q05) AH, BF 14:52 6.75 56 110 17.1 stagnant pool, no flow
2012/09 (Q06) AH, AS 15:45 dry[1]
2012/12 (Q07) BF, SD 13:55 7.00 38 78 11.0 moderate flow
2013/03 (Q08) AH, JK, DT, BO 13:50 7.82 37 74 4.0 low flow
2013/06 (Q09) AH 9:57 7.26 36 72 13.7 low flow
2013/09 (Q10) ASo, AT, DT, JV, SD 10:14 7.35 37 78 14.3 sulfuric smell, low flow
2014/01 (Q11) JV, MP 9:50 7.81 49 94 3.2 light flow
2014/03 (Q12) BO, ET, JK, DT 13:43 6.44 37 78 4.2 very low
2014/06 (Q13) ET, MP 11:00 7.65 42 81 20.1 low flow
2014/09 (Q14) BO, IT, BF 13:14 6.98 46 95 19.5 disconnected standing pools
2014/12 (Q15) ET, GM 11:57 6.05 43 89 3.0 low flow
2015/03 (Q16) TH, BF 13:38 7.40 39 78 4.1 none
2015/06 (Q17) TH, BF 16:00 7.64 36 72 22.4 low flow
2015/09 (Q18) NH, BF, CH 16:09 6.92 121 239 20.2 very low flow
2015/12 (Q19) NH, BFo, MG 13:35 7.90 47 101 10.4 very low flow
2016/03 (Q20) BO, SJ, GO 12:14 7.89 36 72 6.3 low flow
2016/06 (Q21) BO, GO, MH 13:07 7.65 44 89 19.5 very low flow / puddles
2016/09 (Q22) BO, CW, GO 12:37 5.98 89 174 22.6 puddle, not flowing
2016/12 (Q23) BO, MH, GO 14:14 7.07 36 72 3.0 high flow
2017/03 (Q24) BO, CW, AL, ST 16:15 6.62 36 74 10.1 moderate flow
2017/06 (Q25) NH, CW 10:59 6.52 33 72 10.0 moderate flow
2017/09 (Q26) BO, DM, EP, RB 15:06 6.95 50 99 20.5 low flow
2017/12 (Q27) BO, DM, LB 15:28 8.08 43 86 3.4 medium -high flow
2018/03 (Q28) BO, ZH 17:27 8.45 30 61 3.1 medium-high flow
Averages: 7.23 46 92 11.3
Standard Deviations: 0.64 20 38 7.3

Notes

  1. ^ A site denoted as "dry" indicates an active sampling site that has little or no water present for field measurements.