Site A18

From Beaver Run Project
Jump to: navigation, search

This is a summary report of all data for Aikens Pad site 18.

See Interpreting field and lab reports for more detailed information about the data in these tables.

Field Data Summary

Below is a field data summary report for this site, including averages and standard deviations of all measureable parameters. Collector initials are explained here.

Date Collector(s) Time pH TDS (ppm) Cond.(μS) Temp.(°C) Comments
2011/05 (Q01) NF, JW no data
2011/09 (Q02) RC, BO 16:41 6.75 143 287 11.8 low flow at ditch near pad site
2011/12 (Q03) RC 14:34 6.98 95 184 10.8 low flow
2012/03 (Q04) RC, BF 14:41 7.33 90 182 8.5 low flow, convergence point
2012/06 (Q05) AH, AS, SD, BO 10:43 7.32 522 1070 13.4 very low flow
2012/09 (Q06) not sampled
2012/12 (Q07) BF, AT 12:28 dry[1]
2013/03 (Q08) AH, JK, BO 12:40 7.45 120 240 9.0 low flow
2013/06 (Q09) AH, DT, JV 15:07 7.30 95 184 12.6 low flow
2013/09 (Q10) ASo, DT, JV 13:48 7.86 109 217 15.0 moderate flow
2013/12 (Q11) BF, MP, JV 11:00 dry
2014/03 (Q12) JV, MP 14:25 7.87 84 167 11.3 moderate flow
2014/06 (Q13) JV, MP 12:05 7.93 73 150 15.0 moderate flow
2014/09 (Q14) TH, SD not sampled
2014/12 (Q15) ET, SDe, BO 10:41 7.38 102 204 10.5 very low flow
2015/03 (Q16) TH, SD, AG 11:00 6.39 60 121 8.0 none
2015/06 (Q17) TH, BF 11:15 6.90 66 130 13.9 low flow
2015/09 (Q18) BF, PM, CH 10:45 7.72 92 187 18.1 very low flow
2015/12 (Q19) BFo, NH 10:50 7.48 70 143 9.8 low flow
2016/03 (Q20) BFo, NH, PM 10:46 6.81 57 109 8.7 low flow
2016/06 (Q21) NH, JL, JC 11:55 7.56 75 150 16.5 low flow
2016/09 (Q22) NH, JL, SJ, MH too low to sample
2016/12 (Q23) NH, CW 11:12 5.95 219 438 9.8 moderate-high flow
2017/03 (Q24) NH, CW, MH 10:56 6.90 129 255 10.8 moderate flow
2017/06 (Q25) NH, SJ 11:06 6.53 146 291 13.4 high flow
2017/09 (Q26) BO, DM, EP, SJ, RB 12:32 7.67 168 339 17.9 almost too low to sample
2017/12 (Q27) DM, EP, EG 11:20 150 301 6.1 low flow
2018/03 (Q28) DM, EP, EG 14:19 6.37 132 265 4.6 low flow
Averages: 7.16 127 255 11.6
Standard Deviations: 0.56 97 199 3.6

Notes

  1. ^ A site denoted as "dry" indicates an active sampling site that has little or no water present for field measurements.